Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Brain Struct Funct ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38546871

RESUMO

For at least 150,000 years, the human body has been culturally modified by the wearing of personal ornaments and probably by painting with red pigment. The present study used functional magnetic resonance imaging to explore the brain networks involved in attributing social status from face decorations. Results showed the fusiform gyrus, orbitofrontal cortex, and salience network were involved in social encoding, categorization, and evaluation. The hippocampus and parahippocampus were activated due to the memory and associative skills required for the task, while the inferior frontal gyrus likely interpreted face ornaments as symbols. Resting-state functional connectivity analysis clarified the interaction between these regions. The study highlights the importance of these neural interactions in the symbolic interpretation of social markers on the human face, which were likely active in early Homo species and intensified with Homo sapiens populations as more complex technologies were developed to culturalize the human face.

2.
Ann Cardiol Angeiol (Paris) ; 70(3): 161-167, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33958189

RESUMO

PURPOSE: Spontaneous coronary artery dissection (SCAD) may occur in middle age population without any cardiovascular risk factor. We retrospectively evaluated anatomic features of 11 patients with SCAD using a coronary arteries computed tomography (CCT), compared to age and sex balanced patients who underwent CCT. MATERIAL AND METHODS: CCT was performed in 11 patients (7 females and 4 males) as follow-up in patients with SCAD (left anterior descending - LAD or circumflex artery - Cx) and compared, using the propensity score matching analysis, with 11 healthy patients. Several anatomic features were evaluated: Left main (LM) length, angle between descending coronary artery (LAD) and its first branch, angle between LAD and LM, distance from the annulus to RCA (a-RCA distance) and LM (a-LM distance) ostia and their ratio; ratio between LM length and length a-LM and tortuosity score of the vessel with SCAD. A fluid dynamic analysis has been performed to evaluate the effects on shear stress of vessels wall. RESULTS: LM length was significantly shorter in patients with SCAD versus healthy subjects (P=0.01) as well as LM length/a-LM (P=0.03) and the angle between LAD and the first adjacent branch was sharper (P<0.01). Tortuosity score showed a statistically significant difference between groups (P<0.001). Fluid dynamic analysis demonstrates that, in SCAD group, an angle<90 degree is present at the first bifurcation and it can be a cause of increased strain on vessel wall in patients with high tortuosity of coronary artery. CONCLUSION: Tortuosity and angle between the LAD and the adjacent arterial branch combined may determine increased shear stress on the vessel wall that increases the risk of SCAD.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Pontuação de Propensão , Doenças Vasculares/congênito , Fatores Etários , Estudos de Casos e Controles , Anomalias dos Vasos Coronários/etiologia , Anomalias dos Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Feminino , Hemorreologia/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/etiologia , Doenças Vasculares/fisiopatologia
3.
Science ; 367(6485)2020 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-32217702

RESUMO

Marine food-reliant subsistence systems such as those in the African Middle Stone Age (MSA) were not thought to exist in Europe until the much later Mesolithic. Whether this apparent lag reflects taphonomic biases or behavioral distinctions between archaic and modern humans remains much debated. Figueira Brava cave, in the Arrábida range (Portugal), provides an exceptionally well preserved record of Neandertal coastal resource exploitation on a comparable scale to the MSA and dated to ~86 to 106 thousand years ago. The breadth of the subsistence base-pine nuts, marine invertebrates, fish, marine birds and mammals, tortoises, waterfowl, and hoofed game-exceeds that of regional early Holocene sites. Fisher-hunter-gatherer economies are not the preserve of anatomically modern people; by the Last Interglacial, they were in place across the Old World in the appropriate settings.


Assuntos
Dieta , Homem de Neandertal , Exoesqueleto , Animais , Arqueologia , Oceano Atlântico , Aves , Cavernas , Peixes , Mamíferos , Nozes , Pinus , Portugal , Alimentos Marinhos , Tartarugas
4.
R Soc Open Sci ; 6(7): 190086, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31417715

RESUMO

The earliest human graphic productions, consisting of abstract patterns engraved on a variety of media, date to the Lower and Middle Palaeolithic. They are associated with anatomically modern and archaic hominins. The nature and significance of these engravings are still under question. To address this issue, we used functional magnetic resonance imaging to compare brain activations triggered by the perception of engraved patterns dating between 540 000 and 30 000 years before the present with those elicited by the perception of scenes, objects, symbol-like characters and written words. The perception of the engravings bilaterally activated regions along the ventral route in a pattern similar to that activated by the perception of objects, suggesting that these graphic productions are processed as organized visual representations in the brain. Moreover, the perception of the engravings led to a leftward activation of the visual word form area. These results support the hypothesis that these engravings have the visual properties of meaningful representations in present-day humans, and could have served such purpose in early modern humans and archaic hominins.

5.
Phys Med Biol ; 64(8): 085015, 2019 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-30913547

RESUMO

Fricke gel radiochemical sensors based on various matrices have been studied for decades as 3D dosimeters for radiotherapy. Despite their many appealing features, progressive aging and blurring of the signal have prevented the widespread use of these dosimeters, so far. We have addressed these shortcomings and hereby present our development of a Fricke gel based on a chemically cross-linked PVA matrix. We investigated the influence of several parameters of the polymeric matrix on sensitivity, diffusion coefficient and spontaneous oxidation of the proposed gel dosimeter. Based on these findings, we optimized the gel compositions. Our new gel formulation combines transparency, high sensitivity and simple production method, typical of gels based on natural polymers, with low diffusion coefficient and slow spontaneous oxidation typical of PVA gels made by freezing-thawing.


Assuntos
Géis/química , Glutaral/química , Polivinil/química , Dosímetros de Radiação , Reagentes de Ligações Cruzadas/química , Radiometria/instrumentação , Radiometria/métodos
6.
Rev Sci Instrum ; 89(5): 053304, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864841

RESUMO

Superheated emulsions develop visible vapor bubbles when exposed to ionizing radiation. They consist in droplets of a metastable liquid, emulsified in an inert matrix. The formation of a bubble cavity is accompanied by sound waves. Evaporated bubbles also exhibit a lower refractive index, compared to the inert gel matrix. These two physical phenomena have been exploited to count the number of evaporated bubbles and thus measure the interacting radiation flux. Systems based on piezoelectric transducers have been traditionally used to acquire the acoustic (pressure) signals generated by bubble evaporation. Such systems can operate at ambient noise levels exceeding 100 dB; however, they are affected by a significant dead time (>10 ms). An optical readout technique relying on the scattering of light by neutron-induced bubbles has been recently improved in order to minimize measurement dead time and ambient noise sensitivity. Beams of infra-red light from light-emitting diode (LED) sources cross the active area of the detector and are deflected by evaporated bubbles. The scattered light correlates with bubble density. Planar photodiodes are affixed along the detector length in optimized positions, allowing the detection of scattered light from the bubbles and minimizing the detection of direct light from the LEDs. A low-noise signal-conditioning stage has been designed and realized to amplify the current induced in the photodiodes by scattered light and to subtract the background signal due to intrinsic scattering within the detector matrix. The proposed amplification architecture maximizes the measurement signal-to-noise ratio, yielding a readout uncertainty of 6% (±1 SD), with 1000 evaporated bubbles in a detector active volume of 150 ml (6 cm detector diameter). In this work, we prove that the intensity of scattered light also relates to the bubble size, which can be controlled by applying an external pressure to the detector emulsion. This effect can be exploited during the readout procedure to minimize shadowing effects between bubbles, which become severe when the latter are several thousands. The detector we used in this work is based on superheated C-318 (octafluorocyclobutane), emulsified in 100 µm ± 10% (1 SD) diameter drops in an inert matrix of approximately 150 ml. The detector was operated at room temperature and ambient pressure.

7.
Proc Natl Acad Sci U S A ; 115(22): 5798-5803, 2018 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-29760072

RESUMO

Injury to the enteric nervous system (ENS) can cause several gastrointestinal (GI) disorders including achalasia, irritable bowel syndrome, and gastroparesis. Recently, a subpopulation of enteric glial cells with neuronal stem/progenitor properties (ENSCs) has been identified in the adult ENS. ENSCs have the ability of reconstituting the enteric neuronal pool after damage of the myenteric plexus. Since the estrogen receptor ß (ERß) is expressed in enteric glial cells and neurons, we investigated whether a selective ERß agonist, LY3201, can influence neuronal and glial cell differentiation. Myenteric ganglia from the murine muscularis externa were isolated and cultured in either glial cell medium or neuronal medium. In glial cell medium, the number of glial progenitor cells (Sox10+) was increased by fourfold in the presence of LY3201. In the neuronal medium supplemented with an antimitotic agent to block glial cell proliferation, LY3201 elicited a 2.7-fold increase in the number of neurons (neurofilament+ or HuC/D+). In addition, the effect of LY3201 was evaluated in vivo in two murine models of enteric neuronal damage and loss, namely, high-fat diet and topical application of the cationic detergent benzalkonium chloride (BAC) on the intestinal serosa, respectively. In both models, treatment with LY3201 significantly increased the recovery of neurons after damage. Thus, LY3201 was able to stimulate glial-to-neuron cell differentiation in vitro and promoted neurogenesis in the damaged myenteric plexus in vivo. Overall, our study suggests that selective ERß agonists may represent a therapeutic tool to treat patients suffering from GI disorders, caused by excessive neuronal/glial cell damage.


Assuntos
Diferenciação Celular/fisiologia , Proliferação de Células/fisiologia , Receptor beta de Estrogênio/metabolismo , Plexo Mientérico/citologia , Neuroglia/citologia , Neurônios/citologia , Animais , Dieta Hiperlipídica , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Plexo Mientérico/lesões , Neuroglia/metabolismo , Neurônios/metabolismo , Obesidade
8.
Radiat Prot Dosimetry ; 180(1-4): 210-214, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-29697813

RESUMO

In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers 'interrogated' with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.


Assuntos
Emulsões , Nêutrons , Armas Nucleares , Proteção Radiológica/métodos , Espalhamento de Radiação , Carbono/química , Clorofluorcarbonetos/química , Desenho de Equipamento , Análise de Falha de Equipamento , Vidro , Luz , Teste de Materiais , Método de Monte Carlo , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Radiometria , Temperatura , Raios X
9.
Appl Radiat Isot ; 88: 216-20, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24461556

RESUMO

Experimental activities are underway at INFN Legnaro National Laboratories (LNL) (Padua, Italy) and Pisa University aimed at angular-dependent neutron energy spectra measurements produced by the (9)Be(p,xn) reaction, under a 5MeV proton beam. This work has been performed in the framework of INFN TRASCO-BNCT project. Bonner Sphere Spectrometer (BSS), based on (6)LiI (Eu) scintillator, was used with the shadow-cone technique. Proper unfolding codes, coupled to BSS response function calculated by Monte Carlo code, were finally used. The main results are reported here.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Nêutrons/uso terapêutico , Aceleradores de Partículas/instrumentação , Radiometria/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Dosagem Radioterapêutica
10.
Radiat Prot Dosimetry ; 158(2): 216-20, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23960242

RESUMO

Anthropomorphic tissue-equivalent hand phantoms were achieved to measure the extremity dose involved in Zevalin (90)Y-labelling and patient delivering procedure for radioimmunotherapy treatment of non-Hodgkin lymphoma. The extremity doses to hands and wrists of operators were measured by using thermoluminescent detectors mounted on the developed phantoms. Measurements of chest- and lens-equivalent doses performed on a Rando phantom are also reported.


Assuntos
Anticorpos Monoclonais/análise , Mãos/efeitos da radiação , Linfoma não Hodgkin/radioterapia , Imagens de Fantasmas , Radioimunoterapia/métodos , Radiometria/métodos , Radioisótopos de Ítrio/análise , Antropometria , Calibragem , Humanos , Doses de Radiação , Proteção Radiológica , Dosimetria Termoluminescente/métodos , Distribuição Tecidual
11.
Int J Immunopathol Pharmacol ; 25(1): 275-80, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22507341

RESUMO

We describe the case of a 45-year-old woman who had drawn our attention for some recent episodes of transient global amnesia that, upon further examination, resulted from ischemic events caused by multiple arterial thrombosis (bilateral internal carotid occlusion, significant stenosis of the right external carotid, mild stenosis of the right vertebral artery, right anterior cerebral artery occlusion and severe stenosis of the anterior descending coronary artery) due to primary antiphospholipid syndrome. Revascularisation of either carotid was not attempted. A percutaneous intervention in the anterior descending coronary artery stenosis was performed successfully. Due to severe arterial thrombosis, the patient was discharged with only duplex antiplatelet treatment and subcutaneous anticoagulant therapy, since immunotherapy is not indicated in primary APS. The occurrence of transient global amnesia should raise the suspicion of APS.


Assuntos
Amnésia Global Transitória/etiologia , Síndrome Antifosfolipídica/complicações , Feminino , Humanos , Pessoa de Meia-Idade
12.
J Hum Evol ; 60(2): 145-57, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21131024

RESUMO

We report on the analysis of three human cranial fragments from a Mousterian context at the site of La Quina (France), which show anthropogenic surface modifications. Macroscopic and microscopic analyses, including SEM observation, demonstrate that the modifications visible on one of these fragments are similar to those produced on bone fragments used experimentally to retouch flakes. The microscopic analysis also identified ancient scraping marks, possibly resulting from the cleaning of the skull prior to its breakage and utilisation of a resulting fragment as a tool. The traces of utilisation and the dimensions of this object are compared to those on a sample of 67 bone retouchers found in the same excavation area and layer. Results show that the tool size, as well as the dimensions and location of the utilised area, fall well within the range of variation observed on faunal shaft fragments from La Quina that were used as retouchers. This skull fragment represents the earliest known use of human bone as a raw material and the first reported use of human bone for this purpose by hominins other than modern humans. The two other skull fragments, which probably come from the same individual, also bear anthropogenic surface modifications in the form of percussion, cut, and scraping marks. The deliberate versus unintentional hypotheses for the unusual choice of the bone are presented in light of contextual information, modifications identified on the two skull fragments not used as tools, and data on bone retouchers from the same layer, the same site, and other Mousterian sites.


Assuntos
Osso e Ossos , Hominidae , Animais , Arqueologia , Osso e Ossos/anatomia & histologia , Fósseis , França , Humanos , Comportamento de Utilização de Ferramentas
13.
Appl Radiat Isot ; 67(7-8 Suppl): S141-4, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19376712

RESUMO

An accelerator-driven thermal neutron facility for boron neutron capture therapy of skin melanoma is currently under construction at the Legnaro National Laboratories, Italy. The installation relies on the production of neutrons from a thick beryllium target bombarded with 5 MeV protons. A complete set of double differential data, i.e. angle- and energy-differential neutron spectra produced by the beryllium target, is necessary for the Monte Carlo-based design of the installation. For this purpose, double differential fluence measurements are currently performed with the "BINS" neutron spectrometer using 5 MeV protons at the "CN" Van de Graaf accelerator. This spectrometer uses a superheated emulsion of dichlorotetrafluoroethane which is sequentially operated at 25, 30, 35, 40, 45, 50 and 55 degrees C and thus provides a series of seven sharp thresholds covering the 0.1-10 MeV neutron energy interval. Deconvolution of the data is performed with the code "MAXED", which is based on the maximum entropy principle. The analysis of our first neutron spectrometry measurements at angles of 0 degrees, 40 degrees, 80 degrees and 120 degrees supports the viability of the BINS spectrometry method for the generation of the required double differential data.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Terapia por Captura de Nêutron de Boro/estatística & dados numéricos , Nêutrons Rápidos/uso terapêutico , Humanos , Itália , Melanoma/radioterapia , Método de Monte Carlo , Reatores Nucleares , Neoplasias Cutâneas/radioterapia , Análise Espectral
14.
Radiat Prot Dosimetry ; 131(1): 80-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18757899

RESUMO

'Double dosimetry' i.e. measurement with two dosemeters, one located above the protective apron and one under has been recommended in interventional radiology (IR) to determine the effective dose to staff. Several algorithms have been developed to calculate the effective dose from the readings of the two dosemeters, but there is no international consensus on what is the best algorithm. In this work, a few of the most recently developed algorithms have been tested in typical IR conditions. The effective dose and personnel dosemeter readings were obtained experimentally by using thermoluminescent dosemeters in and on a Rando-Alderson phantom provided with a lead apron. In addition, the effective dose and personnel dosemeter readings were calculated by the Monte Carlo method for the same irradiation geometry. The results suggest that most of the algorithms overestimate effective dose in the selected IR conditions, but there is also a risk of underestimation by using the least conservative algorithms. Two of the algorithms seem to comply best with the chosen criteria of performance, i.e. no underestimation, minimum overestimation and close estimation of effective dose in typical IR conditions. However, it might not be justified to generalise the results. It is recommended that whenever personnel doses approach or exceed the dose limit, IR conditions should be further investigated and the possibility of over- or under-estimation of effective dose by the algorithm used should be considered.


Assuntos
Algoritmos , Corpo Clínico , Exposição Ocupacional , Doses de Radiação , Radiometria/instrumentação , Humanos , Método de Monte Carlo , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/métodos
15.
Radiat Prot Dosimetry ; 131(1): 87-92, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18757898

RESUMO

An overview of the use of active personal dosemeters (APD) in interventional radiology is presented. It is based on the work done by the working package 7 of the CONRAD coordinated action supported by the EC within the frame of the 6th FP. This study was done in collaboration with the working package 4 of CONRAD to deal with the calculations required for studying the new calibration facility. The main requirements of the standard for the APD and the difficulties caused by the use of pulsed radiations are presented through the results of an intercomparison organised in a realistic calibration facility similar to the workplace situation in interventional radiology. The main characteristics of this facility are presented.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação/instrumentação , Radiologia Intervencionista , Radiometria/instrumentação , Calibragem , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Monitoramento de Radiação/métodos , Radiometria/métodos
16.
Radiat Prot Dosimetry ; 129(1-3): 333-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18483007

RESUMO

In interventional radiology, for an accurate determination of effective dose to the staff, measurements with two dosemeters have been recommended, one located above and one under the protective apron. Such 'double dosimetry' practices and the algorithms used for the determination of effective dose were reviewed in this study by circulating a questionnaire and by an extensive literature search. The results indicated that regulations for double dosimetry almost do not exist and there is no firm consensus on the most suitable calculation algorithms. The calculation of effective dose is mainly based on the single dosemeter measurements, in which either personal dose equivalent, directly, (dosemeter below the apron) or a fraction of personal dose equivalent (dosemeter above the apron) is taken as an assessment of effective dose. The most recent studies suggest that there might not be just one double dosimetry algorithm that would be optimum for all interventional radiology procedures. Further investigations in several critical configurations of interventional radiology procedures are needed to assess the suitability of the proposed algorithms.


Assuntos
Algoritmos , Exposição Ocupacional/análise , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Radiologia Intervencionista/métodos , Humanos , Radiografia , Inquéritos e Questionários , Glândula Tireoide/diagnóstico por imagem
18.
Radiat Prot Dosimetry ; 126(1-4): 471-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17823130

RESUMO

The availability of active neutron personal dosemeters has made real time monitoring of neutron doses possible. This has obvious benefits, but is only of any real assistance if the dose assessments made are of sufficient accuracy and reliability. Preliminary assessments of the performance of active neutron dosemeters can be made in calibration facilities, but these can never replicate the conditions under which the dosemeter is used in the workplace. Consequently, it is necessary to assess their performance in the workplace, which requires the field in the workplace to be fully characterised in terms of the energy and direction dependence of the fluence. This paper presents an overview of developments in workplace neutron dosimetry but concentrates on the outcomes of the EVIDOS project, which has made significant advances in the characterisation of workplace fields and the analysis of dosemeter responses in those fields.


Assuntos
Ciclotrons , Modelos Biológicos , Nêutrons , Exposição Ocupacional/análise , Radiometria/métodos , Radiometria/tendências , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Masculino , Modelos Estatísticos , Doses de Radiação , Espanha
19.
Radiat Prot Dosimetry ; 124(3): 219-29, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17890781

RESUMO

Within the EC project EVIDOS, 17 different mixed neutron-photon workplace fields at nuclear facilities (boiling water reactor, pressurised water reactor, research reactor, fuel processing, storage of spent fuel) were characterised using conventional Bonner sphere spectrometry and newly developed direction spectrometers. The results of the analysis, using Bayesian parameter estimation methods and different unfolding codes, some of them especially adapted to simultaneously unfold energy and direction distributions of the neutron fluence, showed that neutron spectra differed strongly at the different places, both in energy and direction distribution. The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discussed.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , União Europeia , Humanos , Análise Espectral/métodos , Local de Trabalho
20.
Radiat Prot Dosimetry ; 124(3): 213-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17893081

RESUMO

Ratios of H(p)(10) and H*(10) were determined with reference instruments in a number of workplace fields within the nuclear industry and used to derive workplace-specific correction factors. When commercial survey meter results together with these factors were applied to the results of the locally used personal dosemeters their results improved and became within 0.7 and 1.7 of the reference values or better depending on the response of the survey meter. A similar result was obtained when a correction was determined with a prototype reference instrument for H(p)(10) after adjustment of its response. Commercially available survey instruments both for photon and neutron H*(10) measurements agreed with the reference instruments in most cases to within 0.5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract.


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Fótons , Doses de Radiação , Monitoramento de Radiação/métodos , União Europeia , Humanos , Proteção Radiológica/métodos , Medição de Risco , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...